 MODULE
Mini-spectrometer TM series
C10082CA, C10082CAH, C10083CA, C10083CAH
High sensitivity type (integrated with back-thinned type CCD image sensor)
TM series mini-spectrometers are polychromators integrated with optical elements, an image sensor and a driver circuit. Light to be measured is guided into the entrance port of TM series through an optical fiber and the spectrum measured with the built-in image sensor is output from the USB port to a PC for data acquisition. They are high sensitivity mini-spectrometers employing a back-thinned type CCD image sensor. Their sensitivity is about two orders of magnitudes higher than CMOS type making TM series even more ideal for low-light-level measurement. C10082CAH and C10083CAH are high resolution type (spectral resolution: 1 nm Typ.). Mini-spectrometer TM series comes supplied with free sample software that allows setting measurement conditions, acquiring and saving data, and displaying graphs. Driver software and DLL are also supplied as accessory items to allow the users to configure their own measurement software.
Features
Applications
l Low-light-level measurement such as fluorescence measurement Sensitivity is about two orders of magnitude higher than l Semiconductor process control CMOS type l Evaluation of light source characteristics such as LED l High resolution: 1 nm (C10082CAH, C10083CAH) l High throughput due to transmission grating made of quartz Comparison of CCD type and CMOS type l Highly accurate optical characteristics l Wide spectral response range s Output comparison (relative value) l Easy to install into equipment l Wavelength conversion factor *1 is recorded in internal memory C10082CA C10083CA
s O p tic a l c h a ra c te ris tic s P a ra m e te r S p e c tra l re s p o n s e ra n g e S p e c tra l re s o lu tio n M a x. ( S p e ctr al r e s p o n s e h alf wi dt h) * 2 W a v e le n g th re p ro d u c ib ility * 5 W a v e le n g th te m p e ra tu re d ep ende nce S p e c tra l s tra y lig h t * 2 , * 6 s E le c tric a l c h a ra c te ris tic s P a ra m e te r A /D c o n v e rs io n In te g ra tio n tim e In te rfa c e U S B b us po w er c u rre n t c o n s u m p tio n E x te rn a l p o w e r s u p p ly T M -U V /V IS -C C D T M -V IS /N IR -C C D C 1 0 0 8 2 C A C 10082 CA H C 1 0 0 8 3 C A C 10083 CA H 2 0 0 to 8 0 0 3 2 0 to 1 0 0 0 6 1 *3 0 .2 0 .0 4 -3 3 -3 0 8 *4 1 *3, *4 U n it nm nm nm n m/ C dB
RELATIVE SENSITIVITY *
100 10
1
l Integrated with back-thinned type CCD image sensor:
C10082CAH C10082MD
C10083CAH C10083MD (Typ. Ta=25 C)
10-1
10-2
S p e c ific a tio n 16 1 0 to 1 0 0 0 0 U S B 1 .1 100 5
U n it b it ms mA V
10-3
10
-4
10
-5
200
300
400
500
600
700
800
900
1000
WAVELENGTH (nm) s G e n e ra l ra tin g s / A b s o lu te m a xim u m ra tin g s P a ra m e te r S p e c ific a tio n U n it * A/D count when constant light level enters fiber. KACCB0168EA D im e n s io n s 9 5 (W ) x 9 2 (D ) x 7 6 (H ) mm B a c k -th in n e d ty p e C C D im a g e s e n s o r Im a g e s e n s o r s Measurable optical power (S 1 0 4 2 0 -11 0 6 ) N u m b e r o f p ixe ls 2048 p ix e ls C10082CA (CCD TYPE) S lit (H ) x (V ) * 7 7 0 x 8 0 0 1 0 x 10 0 0 7 0 x 8 0 0 1 0 x 10 0 0 m O p tic a l N A 0 .2 2 0 .11 0 .2 2 0 .11 C o n n e c to r fo r o p tic a l fib e r S M A 905D O p e ra tin g te m p e ra tu re * 8 + 5 to + 4 0 C C10082MD (CMOS TYPE) S to ra g e te m p e ra tu re -2 0 to + 7 0 C *1 : A c o n v e rs io n fa c to r fo r c o n v e rtin g th e im a g e s e n s o r p ixe l n u m b e r in to a w a v e le n g th is re c o rd e d in th e m o d u le . A c a lc u la tio n fa c to r fo r c o n v e rtin g th e 10-15 10-13 10-11 10-9 10-7 A /D c o n v e rte d c o u n t in to th e in p u t lig h t in te n s ity is n o t p ro v id e d . LIGHT POWER * (W) *2 : D e p e n d s o n th e s lit o p e n in g . Va lu e s w e re m e a s u re d w ith th e s lit lis te d in th e * Light power incident on mini-spectrometer through slit ta b le "s G e n e ra l ra tin g s / A b s o lu te m a xim u m ra tin g s ". (=500 nm, integration time: 10 ms to 10000 ms) KACCB0146EA *3 : Ty p ic a l *4 : = 3 2 0 to 9 0 0 nm *5 : M e a s u re d u n d e r c o n s ta n t lig h t in p u t c o n d itio n s *6 : W h e n m o n o c h rom a tic lig h t o f th e follo w in g w a v e le n g th s is in p u t, s p e c tra l s tra y lig h t is d e fin e d a s the ra tio o f th e c o u n t m e a su re d a t th e in p u t w a ve le n g th , to th e c o u n t m ea s u re d in a re g io n o f th e in p u t w a ve le n g th 4 0 n m . C 1 0 0 8 2 C A /C 1 0 0 8 2 C A H : 5 0 0 n m , C 1 0 0 8 3 C A /C 1 0 0 8 3 C A H : 6 5 0 n m *7 : E n tra n c e s lit a p e rtu re s iz e *8 : N o c o n d e n s a tio n
1
Mini-spectrometer TM series
C10082CA, C10082CAH, C10083CA, C10083CAH
Light spectrally separated by a grating is focused according to light wavelength on predetermined image sensor positions, and high-order light is also input onto positions at integer-multiples of wavelengths. In these mini-spectrometers an optical filter is attached to the image sensor to cut off high-order light, but this also causes a drop in the image sensor output at the following wavelengths. C10082CA/10082CAH: Near 340 nm and 500 nm, C10083CA/C10083CAH: Near 500 nm and 700 nm Types not using a high-order light cut-off filter are also available. Please specify by adding "-01" to the type number when ordering. (Example: C10082CA-01)
s Spectral resolution vs. wavelength
8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 200 C10083CA (Slit width 70 m, Optical NA 0.22) C10082CA (Slit width 70 m, Optical NA 0.22) C10083CAH (Slit width 10 m, Optical NA 0.11) C10082CAH (Slit width 10 m, Optical NA 0.11)
SPECTRAL RESOLUTION (nm)
300
400
500
600
700
800
900
1000
WAVELENGTH (nm)
KACCB0159EA
s Optical component layout
TM series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a rugged optical base, making it possible to deliver high throughput and highly accurate optical characteristics.
ENTRANCE SLIT COLLIMATING LENS TRANSMISSION GRATING
s Connection example (transmission light measurement)
Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable measurements are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement setup.
AC ADAPTER (Accessories)
PC
FOCUSING MIRROR
IMAGE SENSOR
KACCC0287EA
HIGH POWER UV-VIS FIBER LIGHT SOURCE (Deuterium lamp and Halogen lamp) L10290
USB CABLE
MINI-SPECTROMETER
FIBER QUARTZ CELL (For holding liquid sample)
KACCC0317EA
2
Mini-spectrometer TM series
C10082CA, C10082CAH, C10083CA, C10083CAH
s Dedicated software package (supplied with unit)
Installing the dedicated software package (containing sample software, device driver, DLL)*9 into your PC allows running the following basic tasks: * Measurement data acquisition and save * Measurement condition setup * Module information acquisition (wavelength conversion factor, polychromator type, etc.) * Graphic display * Arithmetic operation Pixel number to wavelength conversion Dark subtraction Comparison calculation with reference data (transmittance, reflectance) Gaussian approximation (peak position and count, FWHM) Note: Two or more mini-spectrometers can be connected and used with one PC simultaneously. *9: Compatible OS: Microsoft Windows Professional Edition 2000 (SP3 or later) and XP (SP1a or later)
Device driver and DLL for controlling hardware are also provided. You can develop your own measurement programs by using a software development environment that includes Microsoft Visual C++ and Visual Basic.*10 The DLL provides functions such as USB port open/close, measurement condition setup, measurement data and module information acquisition. *10: Operation of the device driver and DLL has been verified only with Microsoft Visual C++(R) and Visual Basic(R). Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States and other countries.
s Measurement example (C10083CA) s Dimensional outline (unit: mm) Fluorescence measurement of quinine solution (1000 ppm)
2500
95
2000
92
AD COUNT
1500
1000
500
76
0 300
400
500
600
700
800
900
1000
WAVELENGTH (nm)
KACCB0145EA KACCA0188EC
3
Mini-spectrometer TM series
s Accessories
C10082CA, C10082CAH, C10083CA, C10083CAH
* USB cable * Dedicated software (sample software, device driver, DLL) * AC adapter (for power supply)
s Options (sold separately)
Optical fibers for light input Type. No A9762-01 Product name Core diameter (m) 600 Specification N.A.=0.22, length 1.5 m, connectorized SMA905D at both ends
Fiber for UV/visible range (resistance to UV)
n
Mini-spectrometer line-up
Type No. Type
TM-UV/VIS-CCD High sensitivity TM-UV/VIS-CCD High resolution
Spectral response range (nm)
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Spectral resolution Max. (nm)
Image sensor
C10082CA C10082CAH
6
200 to 800
1* 6
Back-thinned type CCD image sensor
TM series
C10082MD C10083CA C10083CAH C10083MD C9404CA
TM-UV/VIS-MOS Wide dynamic range TM-VIS/NIR-CCD High sensitivity TM-VIS/NIR-CCD
CMOS linear image sensor
High resolution
TM-VIS/NIR-MOS Wide dynamic range TG-UV-CCD High sensitivity
TG-UV-CCD
320 to 1000
8 (=320 to 900 nm) Back-thinned type CCD image sensor 1* (=320 to 900 nm) 8 3
CMOS linear image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor CMOS linear image sensor
TG series
C9404CAH
C9404MC C9405CA C9405MC C9406GC C9913GC C9914GB
C9407MA
* Typ.
High resolution
TG-UV-MOS
200 to 400
1*
3
Wide dynamic range
TG-SWNIR-CCD High sensitivity
500 to 1100
TG-SWNIR-MOS Wide dynamic range TG-NIR
Back-thinned type 5 (=550 to 900 nm) CCD image sensor
5 (=550 to 1100 nm) 7
900 to 1700
NMOS linear image sensor
TG series
Non-cooled type
TG-cooled NIR-I
Low noise (cooled type)
TG-cooled NIR-II
7
1100 to 2200
340 to 780
InGaAs linear image sensor
Low noise (cooled type)
8
9
CMOS linear image sensor
RC series
RC-VIS-MOS
Spectrometer module
OEM model
Type No.
RC series
Type
RC-VIS-MOS
Spectral response range (nm)
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Spectral resolution Max. (nm)
Image sensor
CMOS linear image sensor
C9409MA
Spectrometer head
340 to 780
9
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. (c)2007 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Smidesvagen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741 Cat. No. KACC1126E02
4
Oct. 2007 DN


▲Up To Search▲   

 
Price & Availability of C10083CA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X